I have a ingersoll-rand 25hp rotary screw(ep-25) compressor.it spits out oil(ssr coolant) when i shut unit down.this is a packaged unit full voltage with modulation(480 volts,3ph,control volt-110)it uses ssr ultra coolant which is very expensive($500.oo) per 5 gal.i live in the bahamas where there is little to no tech-support including factory authorized distributor.i have changed scavenge orifice check valve as indicated by manual.i also changed all filters including coolant and air fiters.i ran out of coolant and had to use 30w non-detergent motor.did this cause problem?i have also noticed

Research, Knowledge and Information :


IR UP6 - lot's of oil carry over | Air Compressor Guide


Coolant oil was added to the compressor this week and the unit has ... the compressor spits out a lot of oil at ... you can get a lot of oil carry over ...
Read More At : www.air-compressor-guide.com...

How do I Add AC Compressor Oil? - BlueDevil Products


How do I Add AC Compressor Oil? ... still after being charged the feon is leaking out should the compressor oil and ... your compressor is a sealed unit and shouldn ...
Read More At : gobdp.com...

Compressor Problem | Air Compressor Guide


I have Ingersoll Rand 15kw screw air compressor problem is this ... it will spit out a lot of oil ... When the compressor stops, this valve should stop almost all ...
Read More At : www.air-compressor-guide.com...

Intake valve issue on Craftsman 12 gal air compressor


Intake valve issue on Craftsman 12 gal air compressor, oil spitting out ... The unit is not running past the cut-out pressure ... gauges are not working. unscrewed 2 ...
Read More At : www.about-air-compressors.com...

Air Compressor Trouble-Shooting, Problems, The Causes, Solutions


Trouble-shoot air compressor problems, find out the cause, ... Air Compressor Trouble Shooting Guide. ... Service unit (change oil, ...
Read More At : www.portlandcompressor.com...

Hydrovane 6PU compressor problems. - Practical Machinist


Hydrovane 6PU compressor problems ... directly into the vane unit in fact with the valve removed ... to some degree so overpressure will push oil out.
Read More At : www.practicalmachinist.com...

Compressor Will Not Run - HVAC Tech Support - LA Air ...


Compressor Will Not Run ... Loss of refrigerant charge may cause the compressor to seize due to lack of oil ... Outdoor Fan Stopped or Cycling on Overload
Read More At : hvactechsupport.com...

How To Repair A Refrigerator With A Compressor That ... - YouTube


Aug 07, 2012 · Kung Fu Maintenance demonstrates how to repair a refrigerator compressor that suddenly stopped working ... with a compressor that ... thing out when I'm ...

Loading ...

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.freddiemercuryandqueen.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0080 seconds